Motor Controllers

HL-M2002A

A motor-controller series for low-power equipment applications with configurable I/O and communication.

HL-M2002A product image

Key parameters

Voltage

24 – 72 V

Peak current

180 A

Protection

IP65

Temperature

-40 – 85 ℃

Cooling

Natural or forced-air cooling

Supported motor types

AC induction motors, Permanent-magnet synchronous motors, Separately excited DC motors

Communication / I/O

Multifunction I/O ports, CAN bus communication

Dimensions

165 × 113 × 51 mm

Model matrix

ModelVoltagePeak currentRated current
HL-M2002A-2424 V180 A Peak value; see catalog for duty condition90 A
HL-M2002A-4848 V130 A Peak value; see catalog for duty condition60 A
HL-M2002A-7272 V110 A Peak value; see catalog for duty condition50 A

Features

  • Power-stage and thermal design for equipment integration.
  • Control functions selected around the motor, feedback device and duty cycle.
  • CAN and I/O configuration confirmed against the vehicle or equipment interface.

Typical application directions: Logistics vehicles, Hydraulic-pump units, Fans, Water pumps, HVAC and thermal systems

Connectors & pin definitions

Multifunction I/O ports, CAN bus communication

Control signal connector · TE 776230-1; Power input / output terminals

Control signal connector

Purpose
Control signal connector
Connector / terminal
TE 776230-1
Applicable models
HL-M2002A-24 / HL-M2002A-48 / HL-M2002A-72
PinSignalFunctionElectrical parameters / notes
1A+Encoder A+ or A
2B+Encoder B+ or B
3Z+Encoder Z+ or Z
4PULSE+Pulse signal+
5PW_ENEnable inputController enable input signal
6DI01Digital input 1Configurable active-high / active-low level
7DI02Digital input 2Configurable active-high / active-low level
8
9
10AIN1Analog input 1Configurable current / voltage type
11AIN2Analog input 2Configurable current / voltage type
12AIN3Analog input 3Configurable current / voltage type
13A-Encoder A-
14B-Encoder B-
15Z-Encoder Z-
16PULSE-Motor pulse signal-
17
18
19
20CAN_NCAN-L
21CAN_PCAN-H
22RS485ARS485-A
23RS485BRS485-B
24DO1Digital output port 1Low-side output; load capacity 4A
25
26
27DO2Digital output port 2High-side output; load capacity 9A
28GNDGroundController ground
29GNDGroundController ground
305V5V outputMaximum current 0.3A
31NTC_INMotor temperature sensor input
32NTC_GNDMotor temperature sensor ground
33
3424V+24V+ supplyController supply 24V+ input
3524V+24V+ supplyController supply 24V+ input

Source: product catalog, series starts on page 12

Power input / output terminals

Purpose
Power input / output terminals
Applicable models
HL-M2002A-24 / HL-M2002A-48 / HL-M2002A-72
PinSignalFunctionElectrical parameters / notes
B+B+Battery positive inputCopper conductor mm² / maximum terminal and insulation dimensions mm: 25/35 , 9.5~ 12; 300V DC/ 150 Arms
B-B-Battery negative inputCopper conductor mm² / maximum terminal and insulation dimensions mm: 25/35 , 9.5~ 12; 300V DC/ 150 Arms
UUOutput phase UCopper conductor mm² / maximum terminal and insulation dimensions mm: 25/35 , 9.5~ 12; 300VAC/ 110 Arms
VVOutput phase VCopper conductor mm² / maximum terminal and insulation dimensions mm: 25/35 , 9.5~ 12; 300VAC/ 110 Arms
WWOutput phase WCopper conductor mm² / maximum terminal and insulation dimensions mm: 25/35 , 9.5~ 12; 300VAC/ 110 Arms

Source: product catalog, series starts on page 12

Wiring

  • Control signals are powered by the vehicle low-voltage supply or traction battery.

    Applicable models: HL-M2002A-24 / HL-M2002A-48 / HL-M2002A-72 · Catalog series starts on page 12

Dimensions & mounting

  • Overall dimensions: Length 165, Width 113, Height 51

    Applicable models: HL-M2002A-24 / HL-M2002A-48 / HL-M2002A-72 · Catalog series starts on page 12

Diagnostics & notes

  • Fault diagnosis, monitoring and protection functions support system reliability.

    Applicable models: HL-M2002A-24 / HL-M2002A-48 / HL-M2002A-72 · Catalog series starts on page 12