xs1 connector
- Purpose
- xs1 connector
- Applicable models
- HL-C2107
| Pin | Signal | Function | Electrical parameters / notes |
|---|---|---|---|
| 1 | PO | Recommended wire size(mm²): 1 Software overcurrent protection preset: 9.5A | |
| 2 | PO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 8.0A | |
| 3 | PO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 5.5A | |
| 4 | PO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 7.0A | |
| 5 | DO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 4.5A | |
| 6 | PO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 5.0A | |
| 7 | PO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 8.0A | |
| 10 | AI | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 11 | Shield ground connection | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 12 | PO | Recommended wire size(mm²): 1 Software overcurrent protection preset: 9.5A | |
| 13 | DO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 4.5A | |
| 14 | DI | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 15 | DI | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 16 | DI | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 17 | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | ||
| 19 | DI | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 20 | DI | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 21 | CANH | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 22 | CANL | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 23 | PO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 4.5A | |
| 24 | DO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 4.5A | |
| 25 | Connected to XS4-11 | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 26 | Connected to XS4-13 | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 27 | Connected to XS4-9 | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 28 | Connected to XS4-10 | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 29 | DO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 4.5A | |
| 30 | PO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 4.5A | |
| 31 | DO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 4.5A | |
| 32 | DI | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 33 | DI | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: \ | |
| 34 | PO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 4.5A | |
| 35 | PO | Recommended wire size(mm²): 0.85 Software overcurrent protection preset: 4.5A |
Source: product catalog, series starts on page 35